MURAL - Maynooth University Research Archive Library



    Development and validation of a real-time microelectrochemical sensor for clinical monitoring of tissue oxygenation/perfusion


    Gnahoré, Gama Theophile and Kelly, Jack L. and O'Riordan, Saidhbhe L. and Bolger, Fiachra B. and Doran, Michelle M. and Sands, Michelle and Lowry, John P. (2020) Development and validation of a real-time microelectrochemical sensor for clinical monitoring of tissue oxygenation/perfusion. Analytical Methods, 12 (19). pp. 2453-2459. ISSN 1759-9660

    [img]
    Preview
    Download (571kB) | Preview


    Share your research

    Twitter Facebook LinkedIn GooglePlus Email more...



    Add this article to your Mendeley library


    Abstract

    Oxygen is of critical importance to tissue viability and there is increasing demand for its reliable real-time clinical monitoring in order to prevent, diagnose, and treat several pathological disorders, including hypoxia, stroke and reperfusion injury. Herein we report the development and characterisation of a prototype clinical O2 sensor, and its validation in vivo, including proof-of-concept monitoring in patients undergoing surgery for carpal tunnel release. An integrated platinum-based microelectrochemical device was custom designed and controlled using a miniaturised telemetry-operated single channel clinical potentiostat. The in vitro performance of different sensor configurations is presented, with the best sensor design (S2) displaying appropriate linearity (R2 = 0.994) and sensitivity (0.569 ± 0.022 nA μM−1). Pre-clinical validation of S2 was performed in the hind limb muscle of anaesthetised rats; tourniquet application resulted in a significant rapid decrease in signal (90 ± 27%, [ΔO2] ca. 140 ± 18 μM), with a return to baseline within a period of ca. 3 min following tourniquet release. Similar trends were observed in the clinical study; an immediate decrease in signal (39 ± 3%, [ΔO2] ca. 30 ± 20 μM), with basal levels re-established within 2 min of tourniquet release. These results confirm that continuous real-time monitoring of dynamic changes in tissue O2 can serve as an indicator of reperfusion status in patients undergoing carpal tunnel surgery, and suggests the potential usefulness of the developed microelectrochemical sensor for other medical conditions where clinical monitoring of O2 and perfusion is important.

    Item Type: Article
    Keywords: Development; validation; real-time microelectrochemical sensor; clinical monitoring; tissue oxygenation/perfusion;
    Academic Unit: Faculty of Science and Engineering > Chemistry
    Faculty of Science and Engineering > Research Institutes > Human Health Institute
    Item ID: 16207
    Identification Number: https://doi.org/10.1039/D0AY00206B
    Depositing User: John Lowry
    Date Deposited: 29 Jun 2022 09:20
    Journal or Publication Title: Analytical Methods
    Refereed: Yes
    URI:
    Use Licence: This item is available under a Creative Commons Attribution Non Commercial Share Alike Licence (CC BY-NC-SA). Details of this licence are available here

    Repository Staff Only(login required)

    View Item Item control page

    Downloads

    Downloads per month over past year

    Origin of downloads